194002522 - N021 HORNS WORKING OUT OF TUNE

1CHECK POSITIONING OF HORNSALL OKPROBLEMS ENCOUNTEREDACTION
Check manually that the horn bracket is securely fastened to the fixing point and that the fixing point does not show signs of damage/breaking.Check that both the horn casing and the bracket are not touching or are not in the immediate vicinity (less than 10 mm) of other objects (other components, cables, pipes, etc.)Move on to Step 21. Bracket fastening faulty1. Renew the correct fastening of the bracket
2. Fixing point damaged/broken2. Replace the fastening element
3. Bracket damaged3. Replace the bracket
4. Horn bracket or casing interfering with other components.4. Eliminate the cause of the interference
2ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Connect a tester in parallel to the horn supply line and check that, whilst it is working, the supply voltage is more than 11.4 VMove on to Step 3The voltage is below 11.4 VCheck the cause of the low power supply and restore the correct supply
if necessary we will process suitable diagnoses for the battery or the alternator
3HORN CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Remove the horn and connect it directly to a battery charger.    Op. 5550B30 L/H OR R/H HORN (ONE) - R+RCheck that a sound produced and that there are no unpleasant noises (knocking/buzzing)Move on to Step 4Problems with the soundReplace the horn    Op. 5550B30 L/H OR R/H HORN (ONE) - R+R
4ELECTRICAL CIRCUIT CHECKALL OKPROBLEMS ENCOUNTEREDACTION
The problem is due to the presence of an irregular electrical absorption source in the electrical equipment.Search for and eliminate this cause
if necessary we will process suitable diagnoses for the battery, alternator and wiring
End of diagnosis