194003027 - 1056B37 INLET OR EXHAUST TIMING PHASE TRANSFORMER SOLENOID - R.R.

Removing ( Refitting )
The procedure for the intake side phase transformer solenoid is described below, carry out the same instructions for the exhaust side solenoid.
1. Disconnect the electrical connection for the phase transformer solenoid, inlet side.
DescriptionConnector
1Inlet side phase transformer solenoid valve    See N092 PHASE SHIFTER SOLENOID VALVE ON INTAKE SIDE
2. Undo the bolt and remove the phase transformer solenoid, inlet side.
Refitting ( Removing ) - Place the inlet side phase transformer solenoid in its housing and tighten the bolt.- Connect the electrical connection for the phase transformer solenoid, inlet side.