194000374 - 1080E28 ENABLEMENT SOLENOID FOR FLOW OF FUEL VAPOUR TO INLET - R+R

Removing ( Refitting ) 1. Disconnect the electrical connection for the solenoid valve.
DescriptionConnector
1Fuel vapour recovery solenoid valve    See L010 FUEL VAPOUR RECOVERY SOLENOID VALVE
2. Loosen the band and disconnect the fuel vapour inlet pipe from the solenoid valve.3. Disconnect the fuel vapour supply pipe from the solenoid valve.4. Remove the solenoid valve from the mounting bracket.
Refitting ( Removing ) - Place the solenoid valve in its seat.
Position the solenoid valve according the direction of the flow of fuel vapours towards the modular chamber as indicated by the arrow stamped on the solenoid valve ribbing.
- Connect the fuel vapour supply pipe to the solenoid valve.- Connect the fuel vapour inlet pipe to the solenoid valve and tighten the band.- Connect the electrical connection for the solenoid valve.
Avoid positioning the electrical connection for the solenoid valve at the bottom.