194000610 - 5040B14 AIR CONDITIONING SYSTEM MULTISTAGE PRESSURE SWITCH - R+R

Removing ( Refitting )
Follow the safety instructions    Op. 5040 AIR CONDITIONING CASING AND COMPONENTS
- Turn the ignition key to the OFF position.- Disconnect the negative battery terminal.
DescriptionConnector
BATTERY    See A001 BATTERY
    Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE    Op. 1048A10 AIR FILTER ASSEMBLY - R.R.1. Release it from the mounting and disconnect the electrical connection (1a) from the air conditioning system linear pressure sensor (1b).Undo the air conditioning system linear pressure sensor and remove it from the pipe.
DescriptionConnector
1aLINEAR SENSOR FOR FANS    See K120 LINEAR SENSOR FOR FANS
Refitting ( Removing ) - Check that the air conditioning system linear pressure sensor is not damaged.- Tighten the air conditioning system linear pressure sensor to the pipe.- Connect the electrical connection for the linear pressure sensor.
DescriptionConnector
LINEAR SENSOR FOR FANS    See K120 LINEAR SENSOR FOR FANS
    Op. 1048A10 AIR FILTER ASSEMBLY - R.R.    Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE- Connect the negative battery terminal.
DescriptionConnector
BATTERY    See A001 BATTERY