198002725 - 1080BA Check on the operation of the upstream Lambda sensor

STEPCHECK TO BE PERFORMEDIF THE CHECK IS NOT OK
1WIRING CONTINUITY CHECK

  • Connect disconnector AD-456 n° 1806590000 between the cable loom coming from the engine management control unit and the Lambda sensor and check the continuity of the wiring between the sensor and the engine management control unit
Repair or, if necessary, replace the wiring between the engine management control unit and the Lambda sensor    See E5050 DIESEL ENGINES ELECTRONIC MANAGEMENT
2CHECK ON THE WIRING INSULATION

  • Check that the wiring is correctly insulated to earth
Repair or, if necessary, replace the wiring between the engine management control unit and the Lambda sensor    See E5050 DIESEL ENGINES ELECTRONIC MANAGEMENT
3CHECK ON HEATER RESISTANCE POWER SUPPLY

  • Turn the ignition key to the ON position
  • Check that the voltage between pin 4 and the earth is about 12 Volt
Restore correct power supply    See E5050 DIESEL ENGINES ELECTRONIC MANAGEMENT
Lambda sensor connectorPINOUT
PinFunction
1Pump current
2Earth reference
3Heater control
4+12 Volt heater power supply
5Current adjustment
6Pumping current