198002813 - 5520C20 HEATER PLUGS CONTROL UNIT - R.R

Removing ( Refitting )     Op. 1016A10 SOUND-PROOFING COVER - R.R 1. Undo nut (1a) fixing preheating control unit (1b) to the partition and rotate it to access the electrical connections.
DescriptionConnector
1bGLOW PLUG PREHEATING CONTROL UNIT    See M015 PLUG PREHEATING CONTROL UNIT
1. Undo nut (1a) and disconnect earth lead (1b).2. Disconnect electrical connections (2a) and (2b), remove the control unit.
DescriptionConnector
1bGLOW PLUG PREHEATING CONTROL UNIT    See M015 PLUG PREHEATING CONTROL UNIT
DescriptionConnector
2aGLOW PLUG PREHEATING CONTROL UNIT    See M015 PLUG PREHEATING CONTROL UNIT
DescriptionConnector
2bGLOW PLUG PREHEATING CONTROL UNIT    See M015 PLUG PREHEATING CONTROL UNIT
Refitting ( Removing ) - Check that the glow heater plug preheating control unit is not damaged.- Connect the electrical connections and tighten the nut securing the earth lead.- Refit the control unit on the partition and tighten the nut.    Op. 1016A10 SOUND-PROOFING COVER - R.R