198003083 - 5010D18 TOP MIXED AIR TEMPERATURE SENSOR - R+R FOLLOWING ELECTRICAL WIRING CHECK WITH HEATER CASE REMOVED (Automatic air conditioning)

Removing ( Refitting ) RIGHT SENSOR1. Extract the sensor, releasing it from the housing (press fit).2. Detach the electrical connection.
DescriptionConnector
2RIGHT UPPER AIR DISTRIBUTION TEMPERATURE SENSOR    See K110 RIGHT UPPER AIR DISTRIBUTION TEMPERATURE SENSOR
3. Keep the sensor.
LEFT SENSOR1. Undo the bolts.2. Move the plate with the air distribution motors.
Take care not to move the linkages controlled by the motors.
1. Extract the sensor, releasing it from the housing (press fit).2. Detach the electrical connection.
DescriptionConnector
2LEFT UPPER AIR DISTRIBUTION TEMPERATURE SENSOR    See K112 LEFT UPPER AIR DISTRIBUTION TEMPERATURE SENSOR
3. Keep the sensor.
Refitting ( Removing ) - Check that the sensor is not damaged.- Attach the electrical connection.- Fit the sensor and attach it.- If necessary, position the plate with the air distribution motors.- Tighten the bolts.- Once the refittings are completed, use an Examiner to check that the system has not acquired errors during the operation.