198001860 - K122 WATER IN DIESEL FILTER WARNING LIGHT OFF (INITIAL TEST NOT CARRIED OUT)

TEST RESULTS
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner diagnostic equipment and check, in Instrument Panel Node mode, that there are no errors and that the parameters are present.Move on to Step 41. Impossible to connect to the NQS2. Presence of errors1. Move on to Step 22. Move on to Step 3
2ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the electricity supply to the Instrument Panel Node is correct.    See E4010 INSTRUMENT PANEL Move on to Step 4Fault in positive electrical supply and/or earthRenew and/or replace the defective component (in the case of a fuse, find out what caused it to blow)
3ERROR CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check for the presence of one or more of the following errors using the Examiner in Instrument Panel Node mode:- CAN line- EEPROM memoryMove on to Step 41. Detected "no additional information" and/or "BUS off"2. Fault in EEPROM memory1. Continue as described by the diagnostic equipment2. Replace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R
4ACTIVE DIAGNOSIS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
With the Examiner check in Active Diagnosis mode that the water in the diesel fuel filter warning light activates correctly.End of diagnosisThe warning light does not flash.Replace the Panel    Op. 5560B10 CONTROL PANEL - R+R