198002193 - 5040C18 RECIRCULATION AIR INTAKE UNIT - R.R WITH AIR CONDITIONING CASING REMOVED

Removing ( Refitting ) 1. Undo bolt (1a) fixing the air intake to air conditioning casing (1b).
1. Disconnect the electrical connector for the recirculation intake actuator.
DescriptionConnector
1OUTSIDE AIR/RECIRCULATION INTAKE FLAP ACTUATOR    See N082 OUTSIDE / RECIRCULATION AIR INTAKE FLAP ACTUATOR
2. Unscrew bolts (2a) securing recirculation intake actuator (2b).- Remove the air recirculation intake actuator.
1. Prise out and remove air recirculation intake actuator transmission linkage.
1. Undo the bolts on the air recirculation intake casing.- Remove the air recirculation intake flaps.
Refitting ( Removing ) - Position the air intake flaps in their housings.- Close and secure the two air intake half-casings by tightening the fixing bolts.- Secure the air intake flap drive linkages.- Position and secure the air recirculation intake actuator by tightening the bolts.- Connect the electrical connector for the air recirculation intake actuator.- Position and secure the air recirculation intake on the climate control system casing by tightening the bolts.