198002201 - 5040C93 LH VENTILATION DISTRIBUTION FLAP - R.R. WITH AIR CONDITIONING CASING REMOVED

Removing ( Refitting ) 1. Disconnect the electric connections for distribution flap drive motors (1a), and for upper left air mixture sensor (1b).
DescriptionConnector
1aAIR DISTRIBUTION FLAP ACTUATOR    See N080 AIR DISTRIBUTION FLAP ACTUATOR
1bLEFT UPPER AIR DISTRIBUTION TEMPERATURE SENSOR    See K112 LEFT UPPER AIR DISTRIBUTION TEMPERATURE SENSOR
- Undo the bolts securing the motor support.2. Remove the support and the motors.
1. Remove the transmission gears from the flap spindles.2. Unscrew the bolts on the flap housing cap.- Remove the flap housing cap and the distribution flaps - left side vent.
Refitting ( Removing ) - Fit the distribution flaps/vents in their respective housings.- Position and secure the flap housing cap by tightening the bolts.- Secure the flap transmission gears.- Secure the distribution motor mounts by tightening the bolts.- Connect the electrical connections for the distribution flap control motors and for the upper left air mixture sensor.