198002789 - N001 CIGAR LIGHTER/CURRENT SOCKET NOT WORKING

When the cigar lighter is pressed or a consumer is connected to the special connection, the cigar lighter / current socket does not work. All the sockets are equipped with a thermal protection device: this protection cuts off the power supply if devices that absorb a lot of energy are connected.
TEST RESULTS
1CIGAR LIGHTER CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the cigar lighter/current socket and, in particular, make sure that the internal thermal protection device has not intervened as the result of overloading.Move on to Step 21. Thermal protection intervened2. Current socket defective3. Cigar lighter defective1. Eliminate the cause of the overloading2. Replace the current socket    Op. 7065C72 FRONT CIGAR LIGHTER SOCKET - R.R. 3. Replace the cigar lighter
2FRONT CIGAR LIGHTER ELECTRICAL CIRCUIT CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the following, in order:- Cigar lighter fuse- Cigar lighter power supply- Correct earth connection    See E3070 CIGAR LIGHTER / CURRENT SOCKET End of diagnosis1. Check the continuity of the protective fuse for the defective component.2. Connection to earth defective.1. Replace fuse F44 in the dashboard junction unit (after having searched for what caused it to blow)2. Restore the earth connection on the tunnel    See E3070 CIGAR LIGHTER / CURRENT SOCKET