198002790 - N002 SUPPLEMENTARY POWER POINTS NOT WORKING

The additional current socket does not work when a consumer is connected to the special connection. All the sockets are equipped with a thermal protection device: this protection cuts off the power supply if devices that absorb a lot of energy are connected.
TEST RESULTS
1CURRENT SOCKET CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the current socket: in particular, make sure that the thermal protection device inside the socket has not been activated as a result of overloading.Move on to Step 21. Thermal protection activated in dashboard.2. Thermal protection activated in rear socket.1. Replace the thermal protection or the current socket2. Replace the thermal protection or the current socketOp. 7065C86 CURRENT SOCKET IN LUGGAGE COMPARTMENT - R.R.
2 ADDITIONAL CURRENT SOCKET ELECTRICAL CIRCUIT CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the following, in order:- Current socket fuse- Services relay- Correct earth connection    See E3070 CIGAR LIGHTER / CURRENT SOCKET End of diagnosis1. Check the continuity of the protective fuse2. Connection to earth defective1. Replace the defective fuse (and find out what could have caused it to blow)2. Restore the earth connection in the area of the left rear light cluster    See E3070 CIGAR LIGHTER / CURRENT SOCKET