2. Undo the bolt and remove the earth lead.- Move the ignition coils electrical connections safely clips.3. Unscrew the nut securing the wiring harness duct.4. Raise the clip and move the wiring harness duct.5. Disconnect the electrical connections from the ignition coils, releasing the wiring harness duct from the stud.
Refitting
(
Removing
)
- Place the ignition coils in their housings and tighten the bolts to the recommended torque.
Component
Fastening
dia
Value (daNm)
Validity
Ignition coils
Bolt
M6
0.9
1.4 16v
- Connect the electrical connections for the ignition coils.- Tighten the the nut securing the wiring harness duct.and fasten the retaining clip.- Connect the earth lead and tighten the bolt.- Secure the electrical connection for the timing sensor. Op. 1016A10 SOUND-PROOFING COVER - R.R