198001671 - A010 ALARM CENTRAL LOCKING NOT WORKING

When the alarm is switched on using the remote control, the system is activated correctly (acoustic/visual signalling and deterrent LED working), but the central locking system is not working.The body computer node, after receiving the alarm engagement/disengagement command sends the signal for closing/opening the doors to the door control unit
TEST RESULTS
0PRELIMINARY CHECKSALL OKPROBLEMS ENCOUNTEREDACTION
Using the mechanical key, check that the central locking system is working properly.Move on to Step 11. Central locking not working2. Inertia switch lock operation1. Continue with the diagnosis of the central locking system    See table P011 CENTRAL LOCKING / NOT WORKING WITH REMOTE CONTROL2. Unlock the inertia switch by turning the key to ON
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner diagnostic equipment and check the following at the body computer node:· no control unit inactive;· no faulty control units;· no control unit with faulty B-CAN lineMove on to Step 2Presence of faultsContinue following the instructions for the diagnostic equipment.
2CHECK DOOR MANAGEMENT CONTROL UNITALL OKPROBLEMS ENCOUNTEREDACTION
Check the continuity of the wiring between the body computer and the door management control unitCheck the continuity/insulation of the wiring between the door management control unit and the central locking systemCheck correct operation of door management control unitEnd of diagnosis1. Defective wiring between body computer and door management control unit2. Defective wiring between body computer and door management control unit and central locking system3. Door management control unit defective1. Restore the correct wiring.2. Restore the correct wiring3. Replace door management control unit    Op. 7005N40 CENTRAL LOCKING ELECTRICAL CONTROL UNIT - R R FOLOWING SYSTEM CHECK
3CHECK ON CORRECT OPERATION OF BODY COMPUTERALL OKPROBLEMS ENCOUNTEREDACTION
Check that the body computer is working properly.End of diagnosisThe fault persistsReplace body computer    Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.