| 1 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Connect the Examiner diagnostic equipment to the diagnostic socket.Check that there are no faults in the instrument panel | Move on to Step 2 | Presence of errors | Continue following the instructions for the diagnostic equipment | 
| 2 | ELECTRICAL CIRCUIT CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check connections between instrument panel, Body Computer and engine management control unit    See E5030  PETROL ENGINES ELECTRONIC MANAGEMENT | Move on to Step 3 | Wiring defective | Repair/replace the wiring. | 
| 3 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Keeping the Examiner equipment connected to the diagnostic socket, check the operation of the display in active diagnosis | Move on to Step 4 | Rev counter not working through stepping motor failure | Replace the Instrument Panel    Op. 5560B10  CONTROL PANEL - R+R | 
| 4 | CORRECT OPERATION CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check that the fault is no longer present | End of diagnosis |  |  |