198001811 - K009 DOORS OPEN CHECK WARNING LIGHT/SYMBOL ON

After having carried out the initial test, the doors open check warning light in the "Instrument Panel Node" remains on constantly.
0PRELIMINARY CHECKSALL OKPROBLEMS ENCOUNTEREDACTION
Check that all four doors are properly shutMove on to Step 1Doors not properly shutShut the doors properly
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the Examiner in the Instrument Panel Node mode, check that there are no errors and that the parameters are presentMove on to Step 21. Impossible to connect to the Instrument Panel control unit.1. Move on to Step 2
2. Presence of errors2. Continue following the instructions on the diagnostic instrument
2CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Using the Examiner check, in the Body Computer Node ambient, that there are no errors and that the door status parameters varyMove on to Step 3The parameters do not changeMove on to Step 4
3ELECTRICAL CONNECTION CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the door switches in the geared motors are working properly.Check the insulation to earth of the connection between the door switches and the Body Computer    See E3040 CENTRAL LOCKING Move on to Step 41.Switches defective1.Replace switches
2.Wiring with imperfect insulation to earth2.Renew wiring insulation
4ACTIVE DIAGNOSIS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
With the Examiner in the Instrument Panel Node ambient check that the doors open check warning light is correctly activated in Active DiagnosisMove on to Step 5The doors open check warning light is not activatedReplace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R
5CORRECT OPERATION CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer presentEnd of diagnosisFault persistsReplace Body Computer    Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.