|  | TEST RESULTS | 
| 1 | INSTRUMENT PANEL FUNCTIONS CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check:- That the display shows the correct time- That it is possible to adjust the time- That the clock moves forward | Move on to Step 2 | 1. The time displayed is not correct2. It is not possible to adjust the time3. The clock stays still4. The display/time is not clear | 1. Adjust the time2. Move on to Step 43. Replace the instrument panel    Op. 5560B10  CONTROL PANEL - R+R 4. Move on to Step 2 | 
| 2 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Connect the Examiner diagnostic equipment to the diagnostic socket.Check that there are no faults in the instrument panel | Move on to Step 3 | Presence of errors | Continue following the instructions for the diagnostic equipment | 
| 3 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Keeping the Examiner equipment connected to the diagnostic socket, check the operation of the display in active diagnosis. | End of diagnosis | Display defective | Replace the instrument panel    Op. 5560B10  CONTROL PANEL - R+R | 
| 4 | ELECTRICAL CIRCUIT CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check:- Connections between centre control panel in dashboard and instrument panel- Control panel earth    See E4010  INSTRUMENT PANEL | Move on to Step 5 | Connections defective, earth or power supply defective | Restore the correct connections, if necessary, replace the wiring. | 
| 5 | MODE BUTTON CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check that the MODE button is working properly see wiring diagram    See E4010  INSTRUMENT PANEL | End of diagnosis | MODE button defective | Replace the left control panel    Op. 7040A56  SWITCH UNIT IN DASHBOARD - R.R. |