198001838 - K060 ABS FAILURE WARNING LIGHT ON

The Brake Node sends the ABS warning light on message via the C-CAN to the Body Computer which makes it available via the gateway to the Instrument Panel Node through the B-CAN.
If there are problems in the C-CAN, the control unit warning lights for this network will light up. The "CAN INFORMATION" check is designed for this eventuality
Test results
0PRELIMINARY CHECKSAll OKProblems encounteredOperation
Connect an EXAMINER and check the following on CAN NETWORK INFORMATION:- No control units inactive- No faulty control units- No control units with faulty CAN lineMove on to Step 11. Fault on CAN network2. Communication with the Body Computer impossible1. Continue following the instructions given by the diagnostic equipment2. Move on to Step 7
1CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Keeping the diagnostic instrument connected, check the following on the BRAKE NODE:- that there are no system/component errors- that there are no CAN faultsMove on to Step 21. System/components faulty2. Fault on C-CAN network1. Continue following the instructions given by the diagnostic equipment2. Move on to Step 9
2CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using the Examiner diagnostic equipment check, in Instrument Panel mode, that there are no errors and that the parameters are present.Move on to Step 3Presence of errorsContinue following the instructions on the diagnostic instrument
3ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check the electricity supply to the Instrument Panel Node is correct.Move on to Step 4Fault in positive electrical supply and/or earthReplace defective component (in the case of a fuse, find out what caused it to blow).
4ELECTRICAL CONNECTIONS CHECKAll OKProblems encounteredOperation
Check the wiring between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connectedMove on to Step 5Electrical connections not operationalRenew the damaged electrical connections
5ACTIVE DIAGNOSIS CHECKAll OKProblems encounteredOperation
With the Examiner in the Instrument Panel Node ambient check that the ABS warning light is correctly activated in Active DiagnosisMove on to Step 6The ABS warning light does not flashReplace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R
6CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using the Examiner check, in the Body Computer Node mode, that there are no errors and that the parameters are present.Move on to Step 91. Impossible to connect to the Body Computer control unit2. Presence of errors3. The parameters do not change1. Move on to Step 72. Continue by following the instructions on the diagnostic instrument3. Move on to Step 9
7ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check the electricity supply to the Body Computer Node is correct.Move on to Step 8Fault in positive electrical supply and/or earthReplace defective component (in the case of a fuse, find out what caused it to blow)
8CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Use an Examiner to check the possibility of connection to the Body Computer NodeMove on to Step 6Impossible to connect to the Body Computer control unitReplace Body Computer    Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.
9CORRECT OPERATION CHECKAll OKProblems encounteredOperation
Check that the fault is no longer presentEnd of diagnosisThe fault persistsReplace the electrohydraulic unit - ABS electronic control unit    Op. 3340A12 ABS HYDRAULIC AND ELECTRONIC CONTROL UNIT - R.R.