|  | TEST RESULTS | 
| 0 | PRELIMINARY CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check that the warning light comes on during the check when the panel is switched on | Move on to Step 2 | The warning light does not come on. | Move on to Step 1 | 
| 1 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Connect the Examiner diagnostic equipment and check at the Instrument Panel Node that the handbrake warning light is working through active diagnosis | Move on to Step 2 | The warning light does not come on / go out on command. | Replace the instrument panel    Op. 5560B10  CONTROL PANEL - R+R | 
| 2 | ELECTRICAL SYSTEM CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check the following, in order:- the continuity of the wiring between the handbrake lever switch and the Body Computer;    See E4010  INSTRUMENT PANEL - the continuity of the wiring between the Body Computer and the Instrument Panel.    See E4010  INSTRUMENT PANEL | Move on to Step 3 | 1. Wiring broken.2. Wiring broken. | 1. Restore correct wiring    See E4010  INSTRUMENT PANEL 2. Restore correct wiring    See E4010  INSTRUMENT PANEL | 
| 3 | BRAKE FLUID LEVEL SIGNALLING SWITCH CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Check the operation of the switch and the connection between the switch and the Body Computer in order    See E4010  INSTRUMENT PANEL | Move on to Step 4 | 1. Switch defective.2. Wiring broken. | 1. Replace the switch    Op. 3330C30  BRAKE FLUID RESERVOIR - R + R AND WASH INSIDE 2. Restore correct wiring    See E4010  INSTRUMENT PANEL | 
| 4 | HANDBRAKE SWITCH CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Switch operation check | Move on to Step 5 | Switch defective | Replace the switch    Op. 3380A10  HANDBRAKE LEVER - R+R | 
| 5 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION | 
|---|
|  | Connect the diagnostic equipment to the Body Computer and check the plausibility of the parameter. | End of diagnosis | Parameter not plausible. | Replace Body Computer    Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R. |