|  |  | Test results | 
| 1 | PRELIMINARY CHECKS | All OK | Problems encountered | Operation | 
|---|
|  | Connect an EXAMINER and check the following on CAN NETWORK INFORMATION:- that there are no inactive control units;- that there are no faulty control units;- no control units with faulty CAN | Move on to Step 2 | 1. Fault on CAN network2. Communication with the Body Computer impossible. | 1. Continue following the instructions given by the diagnostic equipment2. Move on to Step 7 | 
| 2 | SWITCH CHECK | All OK | Problems encountered | Operation | 
|---|
|  | Check the correct operation of the seat belt unfastened warning light switch | Move on to Step 3 | Switch not operating | Replace the lower branch of the belt    Op. 7065A14  ANCHORAGE ROD FOR , (ONE), FRONT SEAT BELT LEFT OR RIGHT - R.R. | 
| 3 | PASSENGER PRESENCE SENSOR CONNECTIONS CHECK | All OK | Problems encountered | Operation | 
|---|
|  | Check that the seat connection is correctly inserted in the connection on the floor | Move on to Step 4 | Passenger presence sensor connector detached from the connection on the vehicle floor | Fit the seat connector correctly with the vehicle floor connector | 
| 4 | WIRING BREAK CHECK | All OK | Problems encountered | Operation | 
|---|
|  | Check for any breaks/tears in the wiring/device using the specific tester | Move on to Step 5 | Presence of cuts/tears in the connecting cables and break in the printed circuit | Replacement of the passenger presence sensor    Op. 7065A34 PASSENGER PRESENCE SENSOR ON FRONT SEAT FOR INDICATING SEATBELT UNFASTENED R R | 
| 5 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation | 
|---|
|  | Keep the diagnostic tester connected and check for CAN faults in the AIR BAG NODE | Move on to Step 6 | 1. Fault on B-CAN network2. Air bag control unit defective | 1. Move on to Step 112. Replace the Air Bag control unit    Op. 5580C14  AIR BAG ECU - R+R | 
| 6 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation | 
|---|
|  | Using the Examiner in the Instrument Panel Node mode, check that there are no errors and that the parameters are present | Move on to Step 7 | Presence of errors | Continue following the instructions on the diagnostic instrument | 
| 7 | ELECTRICAL POWER SUPPLY CHECK | All OK | Problems encountered | Operation | 
|---|
|  | Check the electricity supply to the Instrument Panel Node is correct. | Move on to Step 8 | Fault in positive electrical supply and/or earth | Replace defective component (in the case of a fuse, find out what caused it to blow) | 
| 8 | ELECTRICAL CONNECTIONS CHECK | All OK | Problems encountered | Operation | 
|---|
|  | Check the wiring between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connected | Move on to Step 9 | Electrical connections not operational | Renew the damaged electrical connections | 
| 9 | ACTIVE DIAGNOSIS CHECK | All OK | Problems encountered | Operation | 
|---|
|  | With the Examiner in Instrument Panel Node mode check that the seat belt unfastened warning light is correctly activated in Active Diagnosis | Move on to Step 10 | The seat belt warning light does not come on correctly | Replace the Instrument Panel    Op. 5560B10  CONTROL PANEL - R+R | 
| 10 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation | 
|---|
|  | Using the Examiner in Body Computer Node mode check that there are no errors and that the seat belt status has changed | End of diagnosis | 1. Impossible to connect to the Body Computer control unit2. Presence of errors3. The parameters do not change | 1. Move on to Step 112. Continue by following the instructions on the diagnostic instrument3. Move on to Step 11 | 
| 11 | ELECTRICAL POWER SUPPLY CHECK | All OK | Problems encountered | Operation | 
|---|
|  | Check the electricity supply to the Body Computer Node is correct | Move on to Step 12 | Fault in positive electrical supply and/or earth | Replace defective component (in the case of a fuse, find out what caused it to blow) | 
| 12 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation | 
|---|
|  | Use an Examiner to check the possibility of connection to the Body Computer Node | End of diagnosis | Impossible to connect to the Body Computer control unit | Replace Body Computer    Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R. |