198003756 - 1064B36 PRESSURIZED AIR SUPPLY PIPE TO WASTE GATE ACTUATOR - R.R.

Removing ( Refitting )     Op. 1016A10 SOUND-PROOFING COVER - R.R 1. Adjust the retaining clip and remove the waste gate valve from the mounting bracket.- Open the middle clip retaining the pressurized air supply pipe to the waste gate actuator.2. Loosen the bands (2a) and remove the pressurized air supply pipe to the waste gate actuator (2b).
Refitting ( Removing ) - Connect the pressurized air supply pipe to the waste gate actuator and tighten the bands.- Place the waste gate valve in position on the mounting bracket attaching the retaining clip.- Close the middle clip retaining the pressurized air supply pipe to the waste gate actuator.    Op. 1016A10 SOUND-PROOFING COVER - R.R