|  |  | Test results | 
| 0 | PRELIMINARY CHECKS | All OK | Problems encountered | Operation | 
|---|
|  | As a preliminary step, check the bonnet closes correctly. Check that the wind noise actually comes from the bonnet | Move on to Step 1 | 1. The wind noise is coming from the front doors2. The wind noise is coming from the rear doors.3. The wind noise comes from the windscreen. The wind noise comes from the lower area of the passenger compartment.5. The wind noise is coming from the sun roof6. The wind noise is coming from the rear area | 1. Proceed as instructed    See table T001 WIND NOISE FROM THE FRONT DOORS2. Proceed as instructed    See table T002 WIND NOISE FROM THE REAR DOORS3. Proceed as instructed    See table T006 WINDSCREEN WIND NOISE4. Proceed as instructed    See table T010 PASSENGER COMPARTMENT WIND NOISE, LOWER AREA (UNDERBODY)5. Proceed as instructed    See table T020  WIND NOISE FROM THE SUN ROOF 6. Proceed as instructed    See table T025 WIND NOISE FROM THE REAR AREA | 
| 1 | CHECK ON LOCATION OF WIND NOISE FROM BONNET | All OK | Problems encountered | Operation | 
|---|
|  | Carry out a test to locate the wind noise from the bonnet accurately locate the area where the wind noise is coming from    See Test 7025OA BONNET WIND NOISE LOCALISATION | Move on to Step 2 | 1. The wind noise is coming from the side area of the bonnet2. The wind noise is coming from the area of the grille3. The wind noise is coming from the front area of the bonnet. | 1. Check the foam buffers where the bonnet and the wings are matched at the rear. Also check the condition of wind seals and make sure they are fitted correctly    Op. 7025A62  BONNET LID WEATHERSTRIP - R+R 2. Check for the seal between the bonnet and the radiator grille3. Check the condition of the front wind seal and make sure it is fitted correctly    Op. 7025A62  BONNET LID WEATHERSTRIP - R+R | 
| 2 | FLAME PARTITION CHECK | All OK | Problems encountered | Operation | 
|---|
|  | Check the flame partition. In particular, check:- the plugs are present;- the plugs are correctly fitted.- the bulkhead coupling rubber fittings are installed correctly;- sealant properly applied;- correct installation. | End of diagnosis | Fireproof bulklhead faulty | Renew fireproof bulkhead |