199001825 - K128 GEAR FLASHING IN THE DISPLAY (Robotized gearbox)

Driving with any gear engaged.
Test results
1GEAR ENGAGEMENT CHECKAll OKProblems encounteredOperation
With the engine switched off and the key in the ON position, engage the gear in which the problem occurred and check that it is not flashing in the displayEnd of diagnosisThe gear is flashing in the displayMove on to Step 2
2CONNECTOR CHECKAll OKProblems encounteredOperation
Apply stress to the vehicle wiring/hydraulic unit (20-way) connector to check that there are no loose contacts, then make sure that there is no flashing in the display    See E7051 ROBOTIZED GEARBOX End of diagnosisThe gear is flashing in the displayMove on to Step 3
3ERRORS IN AUTOMATED GEARBOX CONTROL UNIT CHECKAll OKProblems encounteredOperation
Check that there are no errors in the automated gearbox control unit. More specifically:- Engagement sensor error- Selection sensor errorMove on to Step 5One or more errors on the list are presentMove on to Step 4
4CHECKS ON FAULTS ENCOUNTEREDAll OKProblems encounteredOperation
Check the faults by carrying out    See Test 2127OI WHAT TO DO DEPENDING ON THE ERROR PRESENT IN THE ROBOTIZED GEARBOX CONTROL UNITMove on to Step 5Wiring or connections faultyRestore/replace the wiring    See E7051 ROBOTIZED GEARBOX
5ENGAGEMENT/SELECTION SENSORS REPLACEMENTAll OKProblems encounteredOperation
- If no connection / wiring faults are detected and the gear engagement sensor is in error, replace it    Op. 2127E42 HYDRAULIC SELECTION GEARBOX SHIFT POSITION SENSOR - R.R. and check that the reading for the position is correct by carrying out a series of gear changes.- If no connection / wiring faults are detected and the gear selection sensor is in error, replace it    Op. 2127E40 HYDRAULIC SELECTION GEARBOX SPEED SELECTION POSITION SENSOR - R.R. and check that the reading for the position is correct by carrying out a series of gear changes.
It is advisable to mark the two potentiometers so that they can be recognised once they have been removed.
Move on to Step 6
6ENGAGEMENT/SELECTION POTENTIOMETER CONNECTORS CHECKAll OKProblems encounteredOperation
Stress the engagement/selection connectors to check that there are no loose contacts, then check that the gear is not flashing in the displayMove on to Step 7The gear is flashing in the displayRenew/replace the prewiring and the wiring    See E7051 ROBOTIZED GEARBOX
7CORRECT OPERATION CHECKAll OKProblems encounteredOperation
Check that the fault is no longer present.End of diagnosisThe fault persistsContact technical service for further information on the problem