199002375 - 1080E28 ENABLEMENT SOLENOID FOR FLOW OF FUEL VAPOUR TO INLET - R+R

Removing ( Refitting ) - Disconnect the negative battery terminal.1. Disconnect the intermediate rapid connector for the fuel vapour pipe.
1. Connect the electrical connection to the fuel vapour solenoid valve.
DescriptionConnector
1Fuel vapour recovery solenoid valve    See L010 FUEL VAPOUR RECOVERY SOLENOID VALVE
2. Disconnect the rapid connector for the fuel vapour pipe.3. Pull back retaining clip (3a) and remove solenoid (3b).
Refitting ( Removing ) - Refit the fuel vapour solenoid in its seat and connect the fuel vapour pipe quick fitting.- Connect the electrical connection to the fuel vapour solenoid valve.- Connect the intermediate rapid connector for the fuel vapour pipe.- Connect the negative battery terminal.