199003824 - INTRODUCTION - EXHAUST EMISSION CONTROL SYSTEM - FOR VERSIONS WITHOUT DPF

DESCRIPTION OF COMPONENTS

Catalytic converter

The catalytic converter is a post-treatment device for oxidizing the CO, HC and particles transforming them into carbon dioxide (CO2) and water vapour (H20).The catalytic converter consists of a ceramic, honeycomb structure (1) with cells impregnated with platinum (2) which catalyzes the oxidation reactions.The exhaust gases passing through the cells heat the catalyzer triggering off the conversion of the pollutants into inert compounds.The oxidizing chemical reaction of the CO, HC and particles is effective at temperatures of between 200 and 350°C.In effect, above 350°C the sulphur contained in the diesel fuel starts to oxidize producing sulphur dioxide and sulphur trioxide.

LAMBDA PROBE

The linear "UEGO" planar type Lambda sensor is fitted on the catalytic converter and informs the engine management control unit of the combustion progress.The sensor is an oxygen sensor containing two comparative cells that make it possible to measure λ values (ratio between the quantity of intake air and the theoretical quantity of air required for the complete combustion of the fuel injected) between a wide range from λ = 0.7 (rich mixture) to the value in air (λ= (lean mixture).It is used to compare the reading of the air flow meter with the one mapped in the control unit and, if necessary, correct the fuel injection to be within the emission limits.The sensor works by comparing the concentration of oxygen in the reference cell, housed inside the sensor, with the combustion gas flowing inside the comparison cell next to the reference cell. Depending on the resulting imbalance, the engine management control unit regulates a current signal (lp) that rebalances the oxygen content in the comparison cell through an electrochemical action. The value of lp is proportional to the λ value measured according to the graph illustrated below.
In order to activate the operation of the sensor quickly, the sensor contains a heater operated in duty cycle by the engine management control unit according to a calibrated strategy.The two comparison cells and the heater are incorporated in the same planar ceramic element (layers of several ceramic elements) in order to keep the structure compact and guarantee high response and heating speeds for the actual element.
1. Connection lead2. Protective sleeve3. Planar sensor element4. Ceramic support pipe5. Sensor seat6. Ceramic seal7, Protective pipe

ELECTRICAL SPECIFICATIONS:

  • Max 7.5 V heater power supply from control unit
  • Heater resistance 3.2 ± 0.8 Ω
Pin out1. Pumping current (lp)2. Virtual mass3. Heater (-)4. Heater (+)5. Calibration current6. Nerst voltage