199000837 - K033 DOORS OPEN CHECK WARNING LIGHT ON

After the initial test, the light check warning light on the Instrument Panel Node remains on.
Results of the tests
0PRELIMINARY CHECKSAll OKProblems encounteredOperation
Press the parking light activation button, move the steering wheel stalk and check the parking lights come on.Press the emergency light switch and check they activate correctly.Then turn the key ON and check the operation of the side lights/number plate lights.Activate the rear fog lamp from the control panel and check they operate correctly.Operate the side lights from the stalk and check they operate correctly.Press the brake pedal and check the brake lights come onMove on to Step 11. Parking lights do not work2. Side lights/number plate lights do not work3. Hazard warning lights do not work4. Direction indicators do not work5. Rear fog lamps do not work6. Brake lights do not work1. Continue as indicatedSee table I002 PARKING LIGHTS NOT WORKING2. Continue as indicated    See table I001 SIDE LIGHTS/NO. PLATE LIGHTS NOT WORKING 3. Continue as indicated    See table I039 DIRECTION INDICATORS NOT WORKING WHEN HAZARD WARNING LIGHT SWITCH IS PRESSED 4. Continue as indicated    See table I010 DIRECTION INDICATORS / HAZARD WARNING LIGHTS NOT WORKING 5. Continue as indicated    See table I021 REAR FOG LAMPS NOT WORKING 6. Continue as indicated    See table I014 BRAKE LIGHTS AND THIRD BRAKE LIGHT NOT WORKING
1CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using an Examiner check, in Instrument Panel mode, that there are no errors and that the parameters are present.Move on to Step 51. Impossible to connect with the Instrument Panel control unit2. Presence of errors1. Move on to Step 22. Continue following the instructions on the diagnostic instrument
2ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check the electricity supply to the Instrument Panel Node is correctMove on to Step 3Fault in positive electrical supply and/or earthReplace defective component (in the case of a fuse, find out what caused it to blow).
3CHECK ELECTRICAL CONNECTIONSAll OKProblems encounteredOperation
Check the wiring between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connected.Move on to Step 4Electrical connections not operationalRenew the damaged electrical connections
4CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using the Examiner, check the possibility of connecting with the Instrument Panel NodeMove on to Step 5Impossible to connect to the instrument panelMove on to Step 7
5ACTIVE DIAGNOSIS CHECKAll OKProblems encounteredOperation
With the Examiner in Instrument Panel Node mode, check that the lights check warning light is correctly activated in Active DiagnosisMove on to Step 6The component in question is not activated.Replace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R
6CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using the Examiner check, in the Body Computer ambient, that there are no errors and that the parameter specified variesMove on to Step 71. Impossible to connect with the Instrument Panel control unit2. Presence of errors3. The parameters do not change1. Move on to Step 72. Continue following the instructions on the diagnostic instrument3. Move on to Step 8
7ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check the electricity supply to the Body Computer Node and the Instrument Panel Node is correct.Move on to Step 8Fault in positive electrical supply and/or earthReplace defective component (in the case of a fuse, find out what caused it to blow).
8CONNECTIONS CHECKAll OKProblems encounteredOperation
Check the continuity of the wiring between the various bulbs and the Body Computer NodeMove on to Step 9Electrical connections not operationalRenew the damaged electrical connections
9CHECK ON CORRECT OPERATIONAll OKProblems encounteredOperation
Check that the fault is no longer presentEnd of diagnosisThe fault persistsReplace the Body Computer Node    Op. 5505A32 BODY COMPUTER - R.R