199000843 - K064 AIR BAG FAILURE WARNING LIGHT ON

The brake fluid warning light remains on with the handbrake released.
The (negative) brake fluid level signal is sent by the sensor to the Body Computer Node which makes it available via the B-CAN to the Instrument Panel Node.The Instrument Panel Node lights up the dedicated warning light and displays the insufficient brake fluid level message; if the warning light is faulty, the appropriate message is displayed.
Results of the tests
0PRELIMINARY CHECKSAll OKProblems encounteredOperation
Connect an EXAMINER and check the following on CAN NETWORK INFORMATION:- no control unit inactive;- no faulty control units;- no control units with faulty CANMove on to Step 11. Fault on CAN network2. Communication impossible with the Body Computer1. Continue following the instructions for the diagnostic equipment2. Move on to Step 2
1CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Keeping the Examiner connected, check the plausibility of the brake fluid level parameter at the Body Computer NodeMove on to Step 41. The parameter is not plausible2. Impossible to connect to the Body Computer control unit.1. Replace body computer    Op. 5505A32 BODY COMPUTER - R.R 2. Move on to Step 2
2ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check the electricity supply to the Body Computer Node is correctMove on to Step 3Fault in positive electrical supply and/or earthReplace defective component (in the case of a fuse, find out what caused it to blow).
3CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Use an Examiner to check the possibility of connection to the Body Computer NodeMove on to Step 4Impossible to connect to the Body Computer control unitReplace Body Computer    Op. 5505A32 BODY COMPUTER - R.R
4BRAKE FLUID LEVEL CHECKAll OKProblems encounteredOperation
Check that the brake fluid level is not lowMove on to Step 8Insufficient brake fluid levelMove on to Step 5
5BRAKE FLUID LEVEL TOP UPAll OKProblems encounteredOperation
Top up the brake fluid level and check that the warning light goes outEnd of diagnosisThe warning light does not go outMove on to Step 6
6CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Keeping the diagnostic equipment connected, check that there are no CAN faults at the BRAKE NODEMove on to Step 7Fault on C-CAN networkMove on to Step 12
7ELECTRICAL SYSTEM CHECKAll OKProblems encounteredOperation
Disconnect the connector from the oil level sensor and check that it is working properlySee Test 3330AA INSUFFICIENT BRAKE FLUID LEVEL SENSOR CHECKMove on to Step 8Brake fluid level sensor defectiveReplace the sensor    Op. 3330C44 BRAKE FLUID MINIMUM W/L SWITCH - R + R
8ELECTRICAL SYSTEM CHECKAll OKProblems encounteredOperation
Check the continuity of the cable from the connector to the Body Computer see wiring diagram    See E4010 INSTRUMENT PANEL Move on to Step 9Lead brokenRestore the correct connection
9CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Connect the Examiner and check that plausibility of the handbrake applied parameter at the Body Computer NodeMove on to Step 10The parameter is not plausibleProceed as instructed    See table K072 HANDBRAKE APPLIED WARNING LIGHT
10CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Keep the Examiner connected and check the operation of the brake fluid level warning light in active diagnosis at the Instrument Panel NodeMove on to Step 11The warning light does not flashReplace instrument panel    Op. 5560B10 CONTROL PANEL - R+R
11ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check the electricity supply to the Instrument Panel Node is correct.Move on to Step 12Fault in positive electrical supply and/or earthReplace defective component (in the case of a fuse, find out what caused it to blow).
12CHECK ELECTRICAL CONNECTIONSAll OKProblems encounteredOperation
Check the wiring between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connected.Move on to Step 13Electrical connections not operationalRenew the damaged electrical connections
13CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Keeping the Examiner connected, check the plausibility of the brake fluid level parameter at the Body Computer NodeEnd of diagnosisThe parameter is not plausibleReplace the Body Computer