199000853 - K095 INSTRUMENT PANEL NOT WORKING

With the ignition ON, some of the warning lights are not timed and the instruments are not working with the engine running.
Results of the tests
0PRELIMINARY CHECKSAll OKProblems encounteredOperation
Connect an EXAMINER and check the following on CAN NETWORK INFORMATION:- No control units inactive- No faulty control units- No control units with faulty CAN lineMove on to Step 11. Fault on CAN network2. Communication impossible with the Body Computer1. Continue following the instructions for the diagnostic equipment2. Move on to Step 5
1CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using an Examiner check, in Instrument Panel mode, that there are no errors and that the parameters are present.Move on to Step 41. Presence of errors2. Communication impossible with the instrument panel1. Continue following the instructions on the diagnostic instrument2. Move on to Step 2
2ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check the electricity supply to the Instrument Panel Node is correct.    See Test 5560BR INSTRUMENT PANEL - CHECK POWER SUPPLYMove on to Step 3Fault in positive electrical supply and/or earthReplace defective component (in the case of a fuse, find out what caused it to blow).
3CHECK ELECTRICAL CONNECTIONSAll OKProblems encounteredOperation
Check the wiring between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connected.Move on to Step 4Electrical connections not operationalRenew the damaged electrical connections
4CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Using an Examiner check, in Body Computer Node mode, that there are no errorsMove on to Step 71. Impossible to connect to the Body Computer control unit.2. Presence of errors1. Move on to Step 52. Continue by following the instructions on the diagnostic instrument
5ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check the electricity supply to the Body Computer Node is correct.Move on to Step 6Fault in positive electrical supply and/or earthReplace defective component (in the case of a fuse, find out what caused it to blow).
6CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
Use an Examiner to check the possibility of connection to the Body Computer NodeMove on to Step 7Impossible to connect to the Body Computer control unit.Replace Body Computer    Op. 5505A32 BODY COMPUTER - R.R
7CHECK ON CORRECT OPERATIONAll OKProblems encounteredOperation
Check that the fault is no longer presentEnd of diagnosisThe fault persistsReplace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R