199000854 - K097 CONTROL PANEL POORLY LIT / NOT LIT

Results of the tests
1ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Check the electricity supply to the Instrument Panel Node is correct.Move on to Step 2Fault in positive electrical supply and/or earthReplace defective component (in the case of a fuse, find out what caused it to blow).
2CHECK ELECTRICAL CONNECTIONSAll OKProblems encounteredOperation
Check the wiring between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connected.    See E4010 INSTRUMENT PANEL Move on to Step 3Electrical connections not operationalRenew the damaged electrical connections
3ACTIVE DIAGNOSIS CHECKAll OKProblems encounteredOperation
With the Examiner in Instrument Panel Node mode, check that the instrument panel light is correctly activated in Active Diagnosis.End of diagnosisThe panel lighting is not activatedReplace the Instrument Panel    Op. 5560B10 CONTROL PANEL - R+R