199000868 - N001 CIGAR LIGHTER/CURRENT SOCKET NOT WORKING

When the cigar lighter is pressed or a consumer is connected to the special connection, the cigar lighter / current socket does not work.
All the sockets are equipped with a thermal protection device: this protection cuts off the power supply if devices that absorb a lot of energy are connected.
Results of the tests
1CIGAR LIGHTER CHECKAll OKProblems encounteredOperation
Check the cigar lighter/current socket and, in particular, make sure that the internal thermal protection device has not intervened as the result of overloadingMove on to Step 2Thermal protection intervenedReplace the cigar lighter/current socket    Op. 7065C72 FRONT CIGAR LIGHTER SOCKET - R.R.
2CIGAR LIGHTER ELECTRICAL CIRCUIT CHECKAll OKProblems encounteredOperation
Check the following, in order:- Cigar lighter fuse- Cigar lighter relay- Cigar lighter power supply and earth- Continuity and insulation of cigar lighter electrical circuit    See E3070 CIGAR LIGHTER / CURRENT SOCKET Move on to Step 31. Component defective2. Connections not correct1. Replace the component (in the case of a fuse, find out what caused it to blow)2. Repair the connections    See E3070 CIGAR LIGHTER / CURRENT SOCKET