199000873 - N021 HORNS WORKING OUT OF TUNE

Results of the tests
1CHECK POSITIONING OF HORNSAll OKProblems encounteredOperation
Check manually that the horn bracket is securely fastened to the fixing point and that the fixing point does not show signs of damage/breaking.Check that both the horn casing and the bracket are not touching or are not in the immediate vicinity (less than 10 mm) of other objects (other components, cables, pipes, etc.)Move on to Step 21. Bracket fastening faulty2. Fixing point damaged/broken3. Bracket damaged4. Horn bracket or casing interfering with other components1. Renew the correct fastening of the bracket2. Replace the fastening element3. Replace the bracket4. Eliminate the cause of the interference
2ELECTRICAL POWER SUPPLY CHECKAll OKProblems encounteredOperation
Connect a tester in parallel to the horn supply line and check that, whilst it is working, the supply voltage is more than 11.4 VMove on to Step 3The voltage is below 11.4 VCheck the cause of the low power supply and restore the correct supply
if necessary we will process suitable diagnoses for the battery or the alternator
3HORN CHECKAll OKProblems encounteredOperation
Remove the horn and connect it directly to a battery charger.    Op. 5550B30 L/H OR R/H HORN (ONE) - R+R Check that a sound produced and that there are no unpleasant noises (knocking/buzzing)Move on to Step 4Problems with the soundReplace the horn    Op. 5550B30 L/H OR R/H HORN (ONE) - R+R
4ELECTRICAL CIRCUIT CHECKAll OKProblems encounteredOperation
The problem is due to the presence of an irregular electrical absorption source in the electrical equipment. Search for and eliminate this cause
if necessary we will process suitable diagnoses for the battery, alternator and wiring
End of diagnosisThe fault persistsContact technical service for further information on the problem