199000874 - N023 HORNS WORKING ENDLESSLY

Results of the tests
1RELAY CHECKAll OKProblems encounteredOperation
Remove the horn relay feed and check that the horns stop making a sound.Swap the relay for the horns T3 (20A) with the one for the main beam headlamps T2 and check that the horns work normallyMove on to Step 21. The horns continue to make a sound even without the relay2. The horns continue to sound without being pressed even after the relays have been swapped1. Restore the correct electrical connections    See E3010 HORNS 2. Restore the relays to their places and move on to Step 3
2RELAY CHECKAll OKProblems encounteredOperation
Check that the main beam headlamps are working properly.If the result is positive, remove the horn relay feed and check that the contacts do not show signs of oxidation or deformationEnd of diagnosis1. The main beam headlamps remain on in all conditions2. There are irregularities at the engine compartment junction unit contacts1. Replace the main beam headlamp relay (which was originally the one for the horns)2. Renew the contacts. If necessary, replace the engine compartment junction unit    Op. 5505A13 ADDITIONAL JUNCTION UNIT IN ENGINE COMPARTMENT - R.R.
3HORN ELECTRICAL CHECKAll OKProblems encounteredOperation
Connect a tester to the horn supply line and check the continuity and the insulation of the lineMove on to Step 4Electrical faults: engine compartment junction unit defectiveReplace the engine compartment junction unit    Op. 5505A13 ADDITIONAL JUNCTION UNIT IN ENGINE COMPARTMENT - R.R.
4STEERING COLUMN SWITCH UNIT CHECKAll OKProblems encounteredOperation
Remove the steering wheel and check that there is nothing preventing the operation of the horn control switchMove on to Step 5Switch stuck in closed positionReplace the steering column switch unit.    Op. 5550A10 STALK UNIT ASSEMBLY - R+R
5ELECTRICAL CIRCUIT CHECKAll OKProblems encounteredOperation
The problem is due to the presence of a short circuit in the electrical system.Search for and eliminate this cause    See E3010 HORNS End of diagnosisThe fault persistsContact technical service for further information on the problem