199002613 - L015 CLIMATE CONTROL NOT HEATING

The climate control is working properly and sends air according to the preset flows but this air does not guarantee the required heating.
Test results
0PRELIMINARY CHECKAll OKProblems encounteredOperation
Check that the engine coolant level is within the preset levels and that the refrigerant fluid circulates correctly in the systemMove on to Step 11. Engine coolant level too low2. Coolant does not circulate correctly: thermostat valve operating incorrectly1.Restore the correct level checking that there are no leaks    Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE See table K025 ENGINE COOLANT TEMPERATURE GAUGE NOT WORKING
1CHECK ON CORRECT CLIMATE CONTROL SYSTEM OPERATIONAll OKProblems encounteredOperation
For versions with automatic climate control;With the engine on and the compressor off, in manual mode with the temperature knob at the maximum hot HI position.Also set the recirculation button to the closed position and set the fan speed to 6 bars (display) and the distribution to front ventilation. Use the diagnostic tester to check that the engine temperature reaches at least 70 °C.Check that the air temperature at the front distribution outlet is greater than 60 °C.End of diagnosisThe temperature of the air coming out of the vents is not the desired oneMove on to Step 2
1CHECK ON CORRECT CLIMATE CONTROL SYSTEM OPERATIONAll OKProblems encounteredOperation
For versions with manual climate control;With the engine on and the compressor off, in manual mode with the temperature knob at the maximum hot HI position.Also set the recirculation button to the closed position and set the fan speed to the 3rd setting and the distribution to front ventilation.Use the diagnostic tester to check that the engine temperature reaches at least 70 °C.Check that the air temperature at the front distribution outlet is greater than 60 °CEnd of diagnosisThe temperature of the air coming out of the vents is not the desired oneMove on to Step 2
2CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
For versions with automatic climate control;Connect the diagnostic equipment and check:- that there are no errors at the air mixing actuators;- that there are no faults in the engine temperature sensorMove on to Step 31. Short circuit error at the air mixture actuators2. Error in the engine temperature sensor1. Move on to Step 32. Continue as described by the diagnostic equipment
2CHECK USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
For versions with manual climate control;Connect the Examiner diagnostic equipment and check that there are no errors in the engine temperature sensorCheck the mixture kinematic components are working properlyMove on to Step 51.Error in the engine temperature sensor2.Check the mixture kinematic components are working properly1. Continue as described by the diagnostic equipment2. Restore the correct operation of the mixture kinematic components
3ELECTRICAL CIRCUIT CHECKAll OKProblems encounteredOperation
For versions with automatic climate control;Check whether the electrical wiring connections are loose:Disconnect and check for damage in the connector contacts/reconnect the connection to the actuator.Check the continuity/insulation of the electrical connection:- of the air mixing actuator/s- the connection on the control unitMove on to Step 41. Electrical connections loose or damaged2. Electrical connection broken or not insulated1. Renew the electrical connections    See E6020 AIR CONDITIONING 2. Restore the continuity/insulation of the electrical connection    See E6020 AIR CONDITIONING
4CHECK ON CORRECT OPERATION USING DIAGNOSTIC EQUIPMENTAll OKProblems encounteredOperation
For versions with automatic climate control;Check for persistent errors in the air mixer actuatorsEnd of diagnosisAir mixing actuator errorMove on to Step 5
5CHECK ON CORRECT OPERATION OF MIXTURE ACTUATOR KINEMATIC MECHANISMAll OKProblems encounteredOperation
For versions with automatic climate control;Visually check the correct operation of the mixer actuator from the climate control unit temperature control knob.Check whether the control on the control unit is interrupted by checking the electrical continuity    See Test 5040DH SEQUENTIAL PROCEDURE FOR CHECKING MIXTURE AND DISTRIBUTION ACTUATOR OPERATIONMove on to Step 61. Incorrect operation of actuator2. Physical impediment to the rotation of the flap3. Incorrect operation of actuator from control on climate control system control unit1. Replace the mixture actuator    Op. 5040D94 AIR CONDITIONING LEFT UPPER AIR DISTRIBUTION FLAP MOTOR (DEFROST) - R.R and/or    Op. 5040D96 AIR CONDITIONING RIGHT UPPER DISTRIBUTION FLAP MOTOR (DEFROST) - R.R 2. If possible, restore the correct operation of the flap, otherwise replace the distributor unit3. Replace the climate control system control unit    Op. 5040D14 CONTROL UNIT WITH AUTOMATIC AIR CONDITIONING CONTROL PANEL - R.R.
6AIR MIXTURE ACTUATOR FLAP CHECKAll OKProblems encounteredOperation
Check that the air mixture actuator flap completes its travel without any impedimentEnd of diagnosis1. Flap travel incomplete2. Flap damaged3. Kinematic mechanism damaged1. Release the air mixture actuator flap from the impediment 2. Replace the flap3. Repair kinematic mechanism