|  |  | Test results | 
| 1 | CHECK ON CORRECT OPERATION OF CLIMATE CONTROL NODE | All OK | Problems encountered | Operation | 
|---|
|  | With the engine started up, set the climate control system control unit to the AUTO position, adjust the temperature knob to 22°C, set the fan speed to 8 bars, then press the recirculation button (check that the symbol appears on the display). Check that the air flow rate varies during the opening/closing of the flap. Also locate the grille in the engine compartment for the air intake casing and check the air intake when switching from recirculation to outside air intake |  | When the control unit is set to the FULL AUTO function and the outside temperature is below 3°C the air intake flap opens automatically to prevent the windscreen from misting up | 
 | Move on to Step 2 | 1. The recirculation symbol does not appear on the display2. The recirculation symbol appears on the display (but the recirculation does not operate) | 1. Move on to Step 42. Move on to Step 2 | 
| 2 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation | 
|---|
|  | Connect the Examiner diagnostic equipment and check:- that there are no errors at the air recirculation actuator;- that there are no faults in the AQS sensor | Move on to Step 5 | 1. Errors in the recirculation actuator.2. Errors in the AQS sensor | 1. Move on to Step 32. Move on to Step 4 | 
| 3 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation | 
|---|
|  | Keeping the Examiner diagnostic equipment connected, check, through active diagnosis,- that the air recirculation is working properly;- that all the LEDs and graphic LCD symbols in the display come on | Move on to Step 5 | 1. Air recirculation actuator not working2. The LED with the recirculation symbol does not light up | 1. Move on to Step 42. Replace the climate control system control unit    Op. 5040D14  CONTROL UNIT WITH AUTOMATIC AIR CONDITIONING CONTROL PANEL - R.R. | 
| 4 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation | 
|---|
|  | - that the recirculation flap is working properly in automatic mode by carrying out the "Pollution sensor test".If the result is negativeSee Test 5040DD CHECK ON POLLUTION SENSOR SIGNAL (AQS) | End of diagnosis | 1. AQS sensor not working2. Wiring faulty | 1.Replace AQS sensor2. Repair the wiring | 
| 5 | CHECK ELECTRICAL CONNECTIONS | All OK | Problems encountered | Operation | 
|---|
|  | Check whether the electrical wiring connections are loose.Remove the control unit from the panel mount, disconnect the wiring connector from the control unit and check visually for any damage to the connector and reconnect correctly to check for false contacts.Remove the oddments pocket and disconnect the connector, inspecting visually for any damage to it and reconnect the electrical connector to the actuator | Move on to Step 6 | Electrical wiring connections loose or damaged | Restore the correct wiring connections | 
| 6 | CHECK ON CORRECT OPERATION OF RECIRCULATION ACTUATOR | All OK | Problems encountered | Operation | 
|---|
|  | Then proceed as follows: with the engine running, switch on the recirculation air intake function manually with the fan at the maximum speed. If the actuator works and the flap is driven, check whether the air flow rate varies during the movement by feeling it. Deactivate the function by returning the actuator to its original condition. Identify the air intake casing grille on the vehicle and check the air intake in the shift from recirculation to outside air and the other way round by feeling with your hand. If the result of the check is positive, do not replace the actuator. If there are further doubts as to the operation of the actuator, it is possible to carry out the check following the instructions described below if the air intake casing is easily accessible.    See Test 5040DE SEQUENTIAL PROCEDURE FOR CHECKING RECIRCULATION ACTUATOR OPERATION | Move on to Step 7 | Incorrect operation of recirculation actuator | Replace the recirculation actuator    Op. 5040D75  AIR CONDITIONING RECIRCULATION FLAP CONTROL MOTOR - R.R | 
| 7 | RECIRCULATION ACTUATOR FLAP CHECK | All OK | Problems encountered | Operation | 
|---|
|  | Visually inspect that the air recirculation actuator flap completes its travel without any hinderance | End of diagnosis | 1. Flap travel incomplete2. Flap damaged3. Kinematic mechanism damaged | 1.Free from air recirculation actuator flap from the impediment2.Replace the flap3.Repair kinematic mechanism |