199000072 - 5040B30 EXPANSION VALVE (ORIFICE TUBE) - R+R

Removing ( Refitting )
Follow the safety instructions    Op. 5040 AIR CONDITIONING CASING AND COMPONENTS
- Drain the coolant.    Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE     Op. 1016A10 SOUND-PROOFING COVER - R.R - Remove the engine compartment components that prevent access to the expansion valve.1. Undo the bolt (1a) and disconnect the connector (1b) for the pipe from the expansion valve (1c).
Seal the connectors that have been disconnected using suitable plugs to prevent dampness and impurities from entering the system.
1. Undo the bolts fixing the expansion valve.2. Remove the expansion valve.3. Keep the gaskets.
Do not reuse the gaskets when refitting.
Refitting ( Removing ) - Check that the expansion valve is not damaged.- Place the new gaskets on the expansion valve then secure it in position using the bolts.
Replace the O rings for the connectors. Only use green coloured seals that are resistant to R134a coolant. Lubricate the connector threads using anti-freeze.
1. Connect the connector (1a) to the expansion valve (1b) and tighten the bolt (1c) to the recommended torque.
ComponentFasteningdia  Value (daNm)Validity
Evaporator inlet/outlet connectorBoltM60.7 ÷ 1.1
- Reposition the components removed previously in the engine compartment.    Op. 1016A10 SOUND-PROOFING COVER - R.R - Repressurize the coolant.    Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE