199000064 - 5040A40 AIR CONDITIONING CONDENSER - R+R
 Removing
		(
		Refitting
Removing
		(
		Refitting )
		)
	|  | Follow the safety instructions. Op. 5040 AIR CONDITIONING CASING AND COMPONENTS | 
|  | Seal the connectors that have been disconnected using suitable plugs to prevent dampness and impurities from entering the system. | 




 Refitting
		(
		Removing
Refitting
		(
		Removing )
	- Check that the condenser is intact and does not show signs of damage or deposits of dirt on the finned surface.- If removed, refit the dehydrating filter by fitting the dehydrating element and cover with filter element. Attach the circlip.
		)
	- Check that the condenser is intact and does not show signs of damage or deposits of dirt on the finned surface.- If removed, refit the dehydrating filter by fitting the dehydrating element and cover with filter element. Attach the circlip.|  | Replace the O rings for the connectors. | 
|  | Only use green coloured seals that are resistant to R134a coolant. | 
|  | Lubricate the connector threads using anti-freeze. | 
| Component | Fastening | dia | Value (daNm) | Validity | 
|---|---|---|---|---|
| Pipe connector on condenser | Bolt | M8 | 1.8 ÷ 2.2 | 