199000072 - 5040B30 EXPANSION VALVE (ORIFICE TUBE) - R+R
 Removing
		(
		Refitting
Removing
		(
		Refitting )
		)
	|  | Follow the safety instructions Op. 5040 AIR CONDITIONING CASING AND COMPONENTS | 
|  | Seal the connectors that have been disconnected using suitable plugs to prevent dampness and impurities from entering the system. | 

|  | Do not reuse the gaskets when refitting. | 

 Refitting
		(
		Removing
Refitting
		(
		Removing )
	- Check that the expansion valve is not damaged.- Place the new gaskets on the expansion valve then secure it in position using the bolts.
		)
	- Check that the expansion valve is not damaged.- Place the new gaskets on the expansion valve then secure it in position using the bolts.|  | Replace the O rings for the connectors. Only use green coloured seals that are resistant to R134a coolant. Lubricate the connector threads using anti-freeze. | 
| Component | Fastening | dia | Value (daNm) | Validity | 
|---|---|---|---|---|
| Evaporator inlet/outlet connector | Bolt | M6 | 0.7 ÷ 1.1 | 