199003080 - P0380 Preheating unit control

This error is detected as a diagnosis of the final control stage (with details of s.c. to earth, s.c. to +Vbatt or open circuit), or if the electronic control module temperature reading is not within the specified limits for at least 0.3 s (wtih detail of excessive temperature).
Test results
0PRELIMINARY CHECKSAll OKProblems encounteredOperation
Check that the error details is not S.C. to earthMove on to Step 2The error detail is S.C. to earthMove on to Step 1
1ELECTRICAL CIRCUIT CHECKAll OKProblems encounteredOperation
Ensure fuse F59 (second from the left on the second row from the bottom) in the engine compartment junction unit has not blown.Move on to Step 2Fuse F59 has blownReplace the engine compartment junction unit    Op. 5505A13 ADDITIONAL JUNCTION UNIT IN ENGINE COMPARTMENT - R.R.
2GLOW PLUG OPERATION CHECKAll OKProblems encounteredOperation
Check that the heater plugs are working properly, by carrying out the    See Test 5520CA CHECK GLOW PLUG OPERATIONEnd of diagnosis