199003101 - P2107 Motorised throttle

This error is detected if the control unit recognizes a malfunction in the circuit through an internal logic evaluation or the switched power supply is less than 10 V.
Test results
0PRELIMINARY CHECKSAll OKProblems encounteredOperation
Delete the errors on the diagnostic equipment.Turn the ignition key OFF and then ON.Check that only the following error is present in the control unit:- P2107Move on to Step 1There is no error presentMove on to Step 2
There are also other errors presentProceed as instructed by the diagnostic tester
1THROTTLE CASING ACTUATOR REPLACEMENTAll OKProblems encounteredOperation
Replace the throttle casing actuator    Op. 1060G50 THROTTLE BODY - R.R End of diagnosis--
2ROAD TESTAll OKProblems encounteredOperation
Carry out a road test trying to reproduce the conditions that caused the appearance of the error. Then check that the following error is present:- P2107Move on to Step 3The error does not occur againIt involves an occasional micro-interruption that is difficult to reproduce: it has no effect on the engine performance and therefore does not require any intervention
3CHECK ON THROTTLE CASING OPERATIONAll OKProblems encounteredOperation
Check that the integrated throttle casing actuator is working properly by carrying out the    See Test 1060GO INTEGRATED THROTTLE BODY OPERATION CHECKEnd of diagnosis--