199000064 - 5040A40 AIR CONDITIONING CONDENSER - R+R
 Removing
		(
		Refitting
Removing
		(
		Refitting )
		)
	|  | Follow the safety instructions. Op. 5040 AIR CONDITIONING CASING AND COMPONENTS | 
|  | Seal the connectors that have been disconnected using suitable plugs to prevent dampness and impurities from entering the system. | 


 Refitting
		(
		Removing
Refitting
		(
		Removing )
	- Check that the condenser is intact and does not show signs of damage or deposits of dirt on the finned surface.- If removed, refit the dehydrating filter and attach the retaining ring.1. Position condenser (1a) and do up retainers (1b).2. Connect the connectors (1a) to the pipe and secure it tightening the bolt (1b) to the recommended torque.
		)
	- Check that the condenser is intact and does not show signs of damage or deposits of dirt on the finned surface.- If removed, refit the dehydrating filter and attach the retaining ring.1. Position condenser (1a) and do up retainers (1b).2. Connect the connectors (1a) to the pipe and secure it tightening the bolt (1b) to the recommended torque.| Component | Fastening | dia | Value (daNm) | Validity | 
|---|---|---|---|---|
| Pipe connector on condenser | Bolt | M8 | 1.8 ÷ 2.2 | 
|  | Replace the O rings for the connectors. Only use green coloured seals that are resistant to R134a coolant. Lubricate the connector threads using anti-freeze. | 