10 ENGINE
1088 ENGINE COOLING
1088D COOLANT PIPES AND HOSES
1088D24 WATER PUMP RIGID COOLANT INLET PIPE - R.R.
199000596 - 1088D24 WATER PUMP RIGID COOLANT INLET PIPE - R.R.
Removing
(
Refitting
)
Op. 0010T20 ENGINE COOLANT - CHANGE
Op. 1048A10 AIR FILTER ASSEMBLY - R.R.
Op. 1072C44 EXHAUST MANIFOLD HEAT SHIELD - R+R
1. Loosen the band and disconnect the hose from the water pump rigid inlet pipe.
1. Loosen the band and disconnect the hose from the water pump rigid inlet pipe.
2. Undo the bolt (2a) and remove the water pump inlet pipe (2b).
3. Remove the seal.
Refitting
(
Removing
)
- Place the water pump rigid inlet pipe, complete with new gasket, in position and secure it using the bolt.
- Connect the hoses to the water pump rigid inlet pipe and tighten the bands.