199000748 - B002 STARTER MOTOR NOT WORKING

When the key is turned to the MAR position, the instruments light up but the starter motor does not turn.
Test results
1STARTER MOTOR CONNECTIONS CHECKAll OKProblems encounteredOperation
Check the connections between battery, ignition switch and starter motor    See E5010 STARTING AND RECHARING Check if the maxi fuse in the battery control unit has blownMove on to Step 2Connections not correctRestore the battery connections    See E5010 STARTING AND RECHARING
Earth lead damagedReplace the lead
Lead between battery and starter motor damagedReplace the lead
Maxi fuse blownReplace the maxi fuse after having ascertained the cause of the problem
2IGNITION SWITCH CHECKAll OKProblems encounteredOperation
Check the condition of the ignition switch and that it is working properlyMove on to Step 3Ignition switch faultRepair or replace the ignition switch    Op. 5520A10 IGNITION SWITCH ASSEMBLY - R+R
3STARTER MOTOR CHECKAll OKProblems encounteredOperation
Check the condition of the starter motor and that it is working properlyEnd of diagnosisFault in the starter motorOverhaul the starter motor
Fault in the starter motor that cannot be repairedReplace the starter motor    Op. 5520B10 STARTER MOTOR - R+R