199000067 - 5040A62 PIPE FROM COMPRESSOR TO EVAPORATOR - R.R

Removing ( Refitting )
Follow the safety instructions    Op. 5040 AIR CONDITIONING CASING AND COMPONENTS
- Drain the coolant    Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE 1. Press the tabs (1a) on the rapid connector (1b), then disconnect the pipe (1c) coming from the compressor, first pushing it upwards and then pulling it downwards.
Seal the connectors that have been disconnected using suitable plugs to prevent dampness and impurities from entering the system.
2. Undo the bolt (2a) and disconnect the connector (2b) from the compressor (2c).3. Remove the pipe.
Refitting ( Removing ) - Check that the pipe from the compressor to the condenser is not damaged and that there are no cracks that could compromise the seal.
Replace the O rings for the connectors. Only use green coloured seals that are resistant to R134a coolant.Lubricate the connector threads using anti-freeze.
1. Place the pipe from the faston connection to the compressor in position.2. Connect the connector (2a) to the compressor and tighten the bolt (2b) to the recommended torque.
ComponentFasteningdia  Value (daNm)Validity
Pipe connector on compressorBoltM60.5 ÷ 0.71.2 8v1.4 8v1.4 16v1.4 16v TJet1.9 Multijet
3. Connect the pipe coming from the compressor to the rapid connector.
- Repressurize the coolant    Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE