2582410 - I10 DIRECTION INDICATORS / HAZARD WARNING LIGHTS / NOT WORKING

With the ignition ON, when the steering column switch unit lever is raised or lowered, the direction indicators do not work. When the button is pressed, the hazard warning lights do not work
Results of the tests
1CHECK WITH EXAMINER DIAGNOSTIC INSTRUMENTAll OKProblems metOperation
Connect the EXAMINER diagnostic equipment to the diagnostic socket.Check that there are no faults in the Body Computer.Continue to Step 2Direction indicators error. Incorrect bulbCheck condition of bulbsContinue to Step 2
2CHECK INDIVIDUAL LIGHTSAll OKProblems metOperation
Check the condition of the individual bulbs and the bulb holder assemblyContinue to Step 3Front bulb damagedReplace the bulb Op.   5550C18 
Damaged rear bulbReplace the bulb Op.   5550C26 
Side repeater damagedReplace the side repeater Op.   5550C22 
Rear bulb holder assembly faultyRepair or replace the rear lights cluster Op.   5540A44 
Front bulb holder assembly faultyRepair or change the front light unit Op.   5540B79 
3STEERING COLUMN SWITCH UNIT CHECKAll OKProblems metOperation
Check that the steering column switch unit is working properly and check that the direction indicators switch is working properly Characteristic of working principle 5550A stalk unitContinue to Step 4Steering column switch unit not working properlyReplace the steering column switch unit Op.   5550A12 
4CHECK HAZARD WARNING LIGHTS SWITCHAll OKProblems metOperation
Check the operation of the hazard warning lights switch See   E2020  DIRECTION INDICATORS / HAZARD WARNING LIGHTS Continue to Step 5Hazard warning lights switch faultyReplace the control panel Op.   5505A24 
5CHECK DIRECTION INDICATORS/HAZARD LIGHTS ELECTRICAL CIRCUITAll OKProblems metOperation

Check, in order:

Continue to Step 6Component defectiveReplace the component involved (if a fuse is involved, search for the cause of the problem)
Connections brokenRestore the connections See   E2020  DIRECTION INDICATORS / HAZARD WARNING LIGHTS
6CHECK ON BODY COMPUTER SUPPLYAll OKProblems metOperation
Check that the Body Computer is supplied correctlyContinue to Step 7Incorrect supplyRestore the correct supply : See   E2020  DIRECTION INDICATORS / HAZARD WARNING LIGHTS
Body Computer faultyReplace the Body Computer Op.   5505A32 
7CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentFault persistsSearch for the fault starting from another symptom'