2582435 - K15 CLOCK NOT WORKING

The clock is not working, whilst the other instrument functions are working normally
Results of the tests
1CHECK CLOCK ELECTRICAL CIRCUITAll OKProblems metOperation

Verify:

Continue to Step 2Component defectiveReplace the component involved (if a fuse is involved, search for the cause of the problem)
Connections brokenRestore connections
2CHECK CLOCKAll OKProblems metOperation
Check instrument operation, particularly the clock function Characteristic of working principle   5560  INSTRUMENT PANEL Continue to Step 3Instrument not workingReplace the instrument Op.   5560B11 
3CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentFault persistsSearch for the fault starting from another symptom'