2582468 - M01 ELECTRIC FRONT WINDOWS / NOT WORKING

With the ignition key in the ON position, when the buttons in the control panel are operated the front electric windows do not work.
Results of the tests
1SWITCH SUPPLY CHECKAll OKProblems metOperation

Check, in order:

Continue to Step 2Component defectiveReplace the component (if a fuse is involved, search for the cause of the problem)
Connections not correctRestore connections
2RELAY CHECKAll OKProblems metOperation

Check, in order:

Continue to Step 3Component defectiveReplace the component (if a fuse is involved, search for the cause of the problem)
Connections not correctRestore connections
3CHECK ON BODY COMPUTERAll OKProblems metOperation
Check that the Body Computer sends the signal to the relay.Continue to Step 4No signalReplace the Body Computer Op.   5505A32 
4FUSE CHECKAll OKProblems metOperation

Check, in order:

Continue to Step 5Component defectiveReplace the component (if a fuse is involved, search for the cause of the problem)
Fuse control box defectiveReplace the fuse box Op.   5505A10 
Connections not correctRestore connections
5SWITCH EARTH CHECKAll OKProblems metOperation
Check the condition of the earth lead for the switches in the control panel See   E3050  ELECTRIC FRONT WINDOWS Continue to Step 6Connections not correctRestore connections
6MOTOR SUPPLY CHECKAll OKProblems metOperation
Check the condition of the cable between the switches in the control panel and the electric window motors See   E3050  ELECTRIC FRONT WINDOWS Continue to Step 7Connections not correctRestore connections
7SWITCH CHECKAll OKProblems metOperation
Check the operation of the switches in the control panel See Test   7005MA  - Continue to Step 8Switches not workingReplace switches Op.   5505A24 
8ELECTRIC WINDOW MOTORS CHECKAll OKProblems metOperation
Check the operation of the electric windows motors: check the continuity of the induction winding for each motor.Continue to Step 9Winding open circuitReplace the motor Op.   7005M21 
9CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentFault persistsSearch for the fault starting from another symptom'