2582490 - P10 CENTRAL LOCKING / NOT WORKING

When the central door locking is operated with the key or remote control (if present), the doors do not open and do not close
Results of the tests
0CHECKING FUSESAll OKProblems metOperation
Check condition of fuses: Continue to Step 1Fuse blownReplace the fuse (then search for the cause of the problem)
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Verify:

  • That there are no faults in the Body Computer
  • Plausibility of parameters
Continue to Step 2Error detected in Body ComputerContinue according to the instructions for the diagnostic equipment
Incoherent parametersContinue according to the instructions for the diagnostic equipment
2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Carry out active diagnosis of central door lockingContinue to Step 3Central door locking not workingReplace the Body Computer Op.   5505A32 
3CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentFault persistsReplace the Body Computer Op.   5505A32  Search for the fault starting from another symptom'