2582491 - P11 CENTRAL LOCKING / NOT WORKING WITH REMOTE CONTROL

When the remote control is operated, the doors do not open/close at all.
Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation
Check the correct operation using the key.Check the remote control battery chargeContinue to Step 1The central locking does not work with the key See table   P10  CENTRAL LOCKING
Battery not working properlyReplace
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Verify:

  • That there are no faults in the Body Computer
  • Plausibility of parameters
Continue to Step 2Error detected in Body ComputerContinue according to the instructions for the diagnostic equipment
Incoherent parametersContinue according to the instructions for the diagnostic equipment
2CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentFault persistsReplace the Body Computer Op.   5505A32  Search for the fault starting from another symptom'