2585354 - 5040A Air conditioning system operational check (temperature)
Basic operation
The test must be carried out at
an ambient temperature of between 20°Χ ανδ 30°Χ.
Close all the doors and windows.Set the gearbox to neutral.Start the engine and run it at a speed of 1250-1300 rpm.Open the central air vents and position a thermometer probe inside.Set the temperature selector to the coldest setting.Set the fan speed selector to 2nd speed.Set the distribution selector to the 'front' position.Activate the air conditioner.Activate recirculationCheck that within 2-4 minutes the thermometer's temperature reading
stabilizes at 8°-11°C.