2584220 - 1040A10 fuel tank - r + r and decant fuel

Removing ( Refitting ) Disconnect the battery negative terminal.Place the car on a ramp.Drain the fuel from the tank using suitable equipment. Adopt protective measures to meet current safety requirements.1. Acting on the levers (1a), lift up the rear seat cushion (1b) and move the floor covering (1c) aside to gain access to the fuel pump flap (1d).
1. Undo the fixing bolts (1a) and remove the protective cover (1b).2. Disconnect the electrical connection for the electric pump.
NameConnector
2EPIC injection pump    See N41 EPIC INJECTION PUMP
Raise the vehicle.    Op. 7055B43 REAR WHEEL ARCH LINER (ONE) LEFT OR RIGHT - R.R.1. Undo the bolts fixing the fuel filler pipe fitting to the bodyshell.2. Undo the bolts fixing the filler pipe to the bodyshell.
1. Unscrew the retaining bolts2. Remove the protection bracket.
1. Disconnect the quick-release fittings of fuel outlet hose (1a) and inlet hose (1b).
1. Position an appropriate stand beneath the tank in order to support it during removal.2. Undo the tank bracket retaining bolts.Lower the hydraulic jack.3. Remove the fuel tank, complete with fuel filler pipe.
Refitting ( Removing ) Position the fuel tank on the stand.Raise the tank and tighten the bolts fixing the tank to the bodyshell to torque.

FasteningComponentØValue(daNm)
-BoltFUEL TANKM82.4
Remove the tank stand.Connect the fuel outlet and inlet hoses.Fit the pipe protection bracket and tighten the fixing bolts.Position the filler pipe in the special housing and tighten the bolts fixing the fuel filler to the bodyshell.    Op. 7055B43 REAR WHEEL ARCH LINER (ONE) LEFT OR RIGHT - R.R.Lower the vehicle.Connect the electrical connection to the electric pump.

NameConnector
-EPIC injection pump    See N41 EPIC INJECTION PUMP
Working from inside the vehicle, fit the protective cover and tighten the fixing bolts.Refit the floor covering.Lower the rear seat fastening it to the securing hooks.Remove the vehicle from the ramp.Refill the car with the recommended fuel. During this operation, use appropriate equipment and adopt protective measures to comply with current safety legislation.Connect the battery negative terminal.Remove the vehicle from the ramp.